Subfloor & prep · Calculator

Subfloor Plywood / OSB Calculator

Enter the floor, choose the panel, a structural tongue-and-groove subfloor or an underlayment panel over an existing floor, and give the joist spacing, and this calculator returns the sheets with cutting waste, the screws per sheet and in total, the boxes, and the tubes of construction adhesive.

Subfloor sheets are easy to count; the fasteners are where people guess. The APA fastening schedule puts screws every 6 inches along panel edges and every 12 inches on the joists in between, so the count depends on the joist spacing. This calculator lays that schedule over each sheet, and for underlayment panels uses the closer grid those need.

Subfloor Plywood / OSB Calculator

Units
What do you know about the floor?
ft
ft
in

For the screw count; underlayment is fastened on a grid instead

%

10% for a rectangle; 15% for a room with many corners

screws

A 5 lb box of 2 1/2 in subfloor screws holds roughly 450

Example result for the starting values. Enter your own and press Calculate.

Sheets to buy

14

448 sq ft of panel for 400 sq ft, 633 screws, 5 tubes of adhesive

Floor area
400 sq ft
Screws
633
Adhesive
5 tubes
Panels, screws and adhesive
Floor area400 sq ft
Panel23/32 in T&G, 4 × 8 ft
Sheets (10% waste)14
Panel bought448 sq ft
Fasteners per sheet43
Screws (5% spare)633
Screw boxes2
Construction adhesive tubes (28 oz)5
Show the arithmetic
  1. Floor area = 20 ft × 20 ft = 400 sq ft
  2. Sheets = 400 sq ft × (1 + 10%) ÷ 32 sq ft = 13.75 → 14
  3. Fasteners per sheet: 7 joist lines: 2 edge lines × 9 (6 in centres over 4 ft) + 5 field lines × 5 (12 in centres) = 43
  4. Screws = 14 × 43 × 1.05 = 633 → 2 boxes
  5. Adhesive ≈ one 28 oz tube per 3 sheets → 5 tubes
  • Lay panels with the long side across the joists, stagger the end joints by at least two joists, and leave the 1/8 in gap the APA recommends at panel ends and edges; the tongue-and-groove edges take care of the long seams.
  • This counts pieces only. Whether the joists and panels are stiff enough for the floor you plan, especially tile, is a question for the span tables and the deflection rules (L/360 for ceramic tile, L/720 for stone).

Shopping list

  • 14 sheets 23/32 in T&G, 4 × 8 ft
  • 2 boxes subfloor screws (633 needed) 2 to 2 1/2 in subfloor screws
  • 5 tubes subfloor construction adhesive, 28 oz

Understanding your result

The headline is the sheets to buy, with the screws and adhesive in the line beneath it. The table gives the panel, the sheets with waste, the panel area bought, the fasteners per sheet, the screws with a spare, the boxes and the adhesive tubes.

Sheets is the floor area plus the cutting waste divided by the panel area. A 4 × 8 ft structural panel is 32 sq ft; the 1/4 in underlayment option uses 4 × 4 ft sheets, which are easier to handle in a small bathroom. Fasteners per sheet follow the schedule. For a structural panel laid with its long side across the joists, an 8 ft sheet lands on a joist line every spacing interval: the two lines at the panel ends get a screw every 6 in over the panel’s 4 ft width, and each line in between gets one every 12 in. For underlayment panels the fasteners go on a grid, every 6 in round the edges and every 8 in in the field.

The adhesive is one 28 oz tube per three sheets on 16 in joists, fewer sheets per tube at closer spacing. For the joists themselves, the floor joist calculator counts pieces; if the panel surface needs flattening before a hard floor, the self-leveling compound calculator; and under tile, the cement board calculator counts the backer that goes on top.

How we calculate this

sheets = floor area × (1 + waste %) ÷ sheet area, rounded up joist lines = 96 in ÷ joist spacing + 1 (structural panel across the joists) per sheet = 2 × 9 (edge lines, 6 in centres) + (lines − 2) × 5 (field lines, 12 in centres) underlayment = edges every 6 in + field grid every 8 in screws = sheets × per sheet × 1.05, rounded up adhesive tubes = sheets ÷ (3 × joist spacing ÷ 16), rounded up

The fastening schedule is the APA’s for single-floor and subfloor panels: 6 in on centre at supported panel edges and 12 in at intermediate supports. Underlayment schedules vary by maker; 6 in edges and an 8 in field grid is a common one. The 1.05 covers stripped and missed screws. The subfloor prep guide explains the panels, gaps and stagger, and the self-leveling guide covers the next step for a floor that is not flat.

The assumptions behind the numbers

Assumption Default Where it comes from
Structural panel 23/32 in T&G, 4 × 8 ft, Span Rating 24 oc APA – The Engineered Wood Association, Engineered Wood Construction Guide
Fastening 6 in at panel edges, 12 in at intermediate supports APA fastening schedule for subfloor and single-floor panels
Underlayment fastening 6 in edges, 8 in field grid Typical underlayment plywood instructions
Joist spacing 16 in on centre The most common US floor framing
Waste 10% Cuts and staggered end joints in a simple room
Screws per box about 450 in a 5 lb box of 2 1/2 in screws Typical packaging
Adhesive one 28 oz tube per 3 sheets on 16 in joists Adhesive maker coverage for a 3/8 in bead

Assumptions last reviewed October 8, 2026.

The calculator counts pieces only. It does not check that the joists and panels are stiff enough for the floor you plan; tile needs a floor that deflects no more than L/360 under load and natural stone L/720, which is a question for the span tables and the panel’s rating. It does not count blocking at unsupported panel edges, which tongue-and-groove edges usually make unnecessary, or the 1/8 in spacing gaps the APA recommends at panel ends and edges, which are not material.

Two worked examples

A 24 × 16 ft room on 16 in joists

23/32 in T&G, 10% waste, glued.

  • Sheets: 384 × 1.10 ÷ 32 = 13.2, rounded up to 14 sheets
  • Per sheet: 7 joist lines; 2 × 9 + 5 × 5 = 43 screws
  • Screws: 14 × 43 × 1.05 = 633, two 5 lb boxes; adhesive 5 tubes

Fourteen sheets and about 630 screws. The adhesive is what makes the floor quiet: screws hold the panel down, glue stops it moving against the joist, which is where squeaks come from.

A 45 sq ft bathroom getting 1/4 in underlayment for vinyl

4 × 4 ft sheets, no adhesive.

  • Sheets: 45 × 1.10 ÷ 16 = 3.1, rounded up to 4 sheets
  • Per sheet: 32 edge screws + 25 field = 57
  • Screws: 4 × 57 × 1.05 = 240, one box

Thin vinyl shows every nail head and every gap in the floor beneath, which is why underlayment is fastened so closely and its joints are filled and sanded before the vinyl goes down.

Where to find your inputs

Floor area. Wall to wall over the joists, including under cabinets if the subfloor runs beneath them.

Panel. The span rating and thickness stamped on the panel; buy what the joist spacing and the floor finish need.

Joist spacing. Measure centre to centre of the joists from below, or from the nail lines of the old subfloor.

Screws per box. On the box; subfloor screws are usually 2 to 2 1/2 in for 23/32 in panels.

Common mistakes

  • Panels running with the joists. The long side goes across the joists, or the panel loses most of its strength.
  • No stagger. End joints in neighbouring rows should be offset by at least two joists.
  • Tight joints. Leave the 1/8 in gap at panel ends and edges for swelling.
  • Skipping the glue. It is what keeps the floor quiet.
  • Thicker panel to fix bouncy joists. Stiffness comes from the joists; add blocking or sister them.
  • Underlayment nailed into the joists. It is fastened into the subfloor, with its joints offset from it.

Questions people ask

How many sheets of plywood for a 400 square foot subfloor?
A 4 × 8 ft sheet is 32 sq ft, so 400 sq ft is 12.5 sheets before waste and 14 with 10% for cuts and staggered joints. A 24 × 16 ft room (384 sq ft) is also 14 sheets with waste.
How many screws per sheet of subfloor?
On 16 inch joists, a 4 × 8 ft sheet laid across the joists crosses 7 joist lines. With screws every 6 inches on the two edge joists and every 12 inches on the five in between, that is about 43 screws a sheet. On 24 inch joists it is about 33.
What thickness of subfloor do I need?
23/32 inch (sold as 3/4 inch) tongue-and-groove plywood or OSB rated 24 inches on centre is the standard for joists up to 24 inches apart. Under tile or stone on 24 inch joists, 7/8 inch or a second layer is the usual answer. The span rating stamped on the panel decides.
Should subfloor be glued and screwed?
Yes, glued with subfloor construction adhesive and screwed or ring-shank nailed is the common practice for a stiff, squeak-free floor. A 28 ounce tube lays a bead on the joists under about three sheets on 16 inch joists.
Plywood or OSB for a subfloor?
Both are accepted when they carry the same APA span rating. Plywood tolerates wetting during construction a little better and holds fasteners slightly better at the edges; OSB is usually cheaper and more uniform. Under resilient floors, an underlayment-grade plywood with a sanded face goes on top of either.
What is underlayment plywood for?
A thin panel, 1/4 to 1/2 inch, laid over a sound subfloor to give a smooth, clean surface for vinyl or to build up a floor to match another. It is fastened into the subfloor on a close grid, not into the joists, with its joints offset from the subfloor's.
Embed this calculator on your site

Paste the code into any page. It is free to use; the only thing we ask is that the credit link under the calculator stays.

See all calculators: embed